Products Page

MX-2

The MX-2 is ideal for the person that tests a few different materials regularly. The MX-2 contains 8 velocities of common materials and two velocities that the user can set using a simple sofware program. The tool’s backlit display is easy to read, even in dim light, and the unit operates for up to 200 hours on a single set of batteries. The MX-2 comes complete, ready to use, and is protected by Dakota Ultrasonics 5 year limited warranty.

Additional DescriptionMore Details
PHYSICAL

  • Weight: 10 ounces
  • Size: 2.5 W x 4.75 H x 1.25 D inches
    63.5 W x 120.7 H x 31.8 D mm
  • Operating Temperature: -20 to 120F (-20 to 50C)
  • Case: Extruded aluminum body / nickel plated aluminum end caps. Resistant to impact and environmentally sealed.

 

KEYPAD

  • Sealed membrane that is resistant to both water and petroleum products.
  • Five tactile-feedback keys.

 

TRANSDUCER

  • Dual element (transmit and receive)
  • 1 to 10 MHz frequency range.
  • Locking quick disconnect Lemo connectors
  • 4 foot cable
  • Custom transducers available for special applications
POWER SOURCE

  • Two 1.5V alkaline or 1.2V NiCad AA cells.
  • Typically operates for 200 hours on alkaline and 130 hours on NiCad.

 

DISPLAY

  • Multi-function 4.5 digit liquid crystal display with 0.500 inch numerals, backlit for use in poor light conditions.
  • Measurements displayed in inches, inches/microsecond, millimeters, and meters/second.
  • Bar graph indicates stability or reading.

 

SOFTWARE

  • Comes complete with cable and software to transfer the velocity to the gauge.

 

 

MEASURING

  • Range: Measures from 0.025 to 19.999 inches (0.63 to 500 millimeters)
  • Switch to select English or metric units.
  • Resolution: 0.001 inch (0.01 millimeter)
  • Velocity Range: .0492 to .3937 in/m s
    1250 to 10,000 meters/sec
  • Built-in: Stainless steel reference disk for probe zeroing.
  • Four readings per second for single point measurements or 16 per second in SCAN mode.
  • Velocity Settings: The MX-2 has 8 set velocities and 2 that are custom to the user’s applications. The set velocities are as follows:
  • 1. Steel 4340 (.233)
    2. Stainless Steel 303 (.223 )
    3. Aluminum 2024 (.251 )
    4. Cast Iron (.179 )
    5. Plexiglass (.106 )
    6. PVC (.094)
    7. Polystyrene (.092)
    8. Polyurethane (.070 )
    9. Custom
    10. Custom

 

CERTIFICATION

  • Factory calibration traceable to national standards.

 

WARRANTY

  • 5 year limited.

$0.00Price:
Loading Updating cart...

MX-2

The MX-2 is ideal for the person that tests a few different materials regularly. The MX-2 contains 8 velocities of common materials and two velocities that the user can set using a simple sofware program. The tool’s backlit display is easy to read, even in dim light, and the unit operates for up to 200 hours on a single set of batteries. The MX-2 comes complete, ready to use, and is protected by Dakota Ultrasonics 5 year limited warranty.

Additional DescriptionMore Details
PHYSICAL

  • Weight: 10 ounces
  • Size: 2.5 W x 4.75 H x 1.25 D inches
    63.5 W x 120.7 H x 31.8 D mm
  • Operating Temperature: -20 to 120F (-20 to 50C)
  • Case: Extruded aluminum body / nickel plated aluminum end caps. Resistant to impact and environmentally sealed.

 

KEYPAD

  • Sealed membrane that is resistant to both water and petroleum products.
  • Five tactile-feedback keys.

 

TRANSDUCER

  • Dual element (transmit and receive)
  • 1 to 10 MHz frequency range.
  • Locking quick disconnect Lemo connectors
  • 4 foot cable
  • Custom transducers available for special applications
POWER SOURCE

  • Two 1.5V alkaline or 1.2V NiCad AA cells.
  • Typically operates for 200 hours on alkaline and 130 hours on NiCad.

 

DISPLAY

  • Multi-function 4.5 digit liquid crystal display with 0.500 inch numerals, backlit for use in poor light conditions.
  • Measurements displayed in inches, inches/microsecond, millimeters, and meters/second.
  • Bar graph indicates stability or reading.

 

SOFTWARE

  • Comes complete with cable and software to transfer the velocity to the gauge.

 

 

MEASURING

  • Range: Measures from 0.025 to 19.999 inches (0.63 to 500 millimeters)
  • Switch to select English or metric units.
  • Resolution: 0.001 inch (0.01 millimeter)
  • Velocity Range: .0492 to .3937 in/m s
    1250 to 10,000 meters/sec
  • Built-in: Stainless steel reference disk for probe zeroing.
  • Four readings per second for single point measurements or 16 per second in SCAN mode.
  • Velocity Settings: The MX-2 has 8 set velocities and 2 that are custom to the user’s applications. The set velocities are as follows:
  • 1. Steel 4340 (.233)
    2. Stainless Steel 303 (.223 )
    3. Aluminum 2024 (.251 )
    4. Cast Iron (.179 )
    5. Plexiglass (.106 )
    6. PVC (.094)
    7. Polystyrene (.092)
    8. Polyurethane (.070 )
    9. Custom
    10. Custom

 

CERTIFICATION

  • Factory calibration traceable to national standards.

 

WARRANTY

  • 5 year limited.

$0.00Price:
Loading Updating cart...

DFX-7+

  • Sizing Toolkits: DAC, AWS, TCG, DGS.
  • Exception visibility in sunlight (AMOLED) color VGA display (320×240 pixels).
  • P.R.F. – 8 to 333 Hz, adjustable.
  • Screen Refresh Rate: Adjustable 60 & 120.
  • Detection: Z-Cross, Flank & Peak.
  • Automatic: probe zero, probe recognition, and Temperature compensation.
  • Measurement: Variety of modes to address a number of applications.
  • Large data storage with multiple formats: Alpha numeric grid and sequential w/auto identifier.
  • Windows PC interface software.
  • 2 year limited warranty.
Additional DescriptionMore Details
GENERAL

  • Size: 2.5W x .5H x 1.24D in (63.5 x 165 x 31.5mm).
  • Weight: 14 ounces (.397kgs), with batteries.
  • Case: Extruded aluminum body with nickel plated aluminum end caps (gasket sealed).
  • Display: 1/4 VGA AMOLED color display (320 x 240 pixels). Viewable area 1.7 x 2.27 in (43.2 x 57.6 mm). 16 color pallete, multiple color options, and variable brightness.
  • Screen Refresh Rate: Selectable 60 or 120Hz.
  • Display Views: Flaw Detector: Full wave, +/- Rectified, or RF. Thickness Gauge: Digits, +/- Rectified, RF, or B-Scan.
  • Timing: Precision 25MHz TCXO with single shot 100 MHz 8 bit ultra low power digitizer.
  • Measurement Gates: Two independent gates (Flaw), and three gates (thickness). Start & width adjustable over full range. Amplitude 5-95%, 1% steps. Positive or negative triggering for each gate with audible and visual alarms.
  • Operating Temperature: 14 to 140F (-10C to 60C).
  • Environmental: Meets IP65 requirements.

 

CALIBRATION

  • Automatic Calibration: Longitudinal (straight), or Shear (angle).
  • Probe Types: Single Contact, Dual, Delay, and Angle .
  • English (in), Metric (mm), or Time (μs).
  • Velocity: 0.0100 to .6300 in/μs (256–16,000 m/s).
  • Test Range: 0 to 0.280in (7.11mm) minimum, to 1200in (30,480mm) maximum at steel velocity. Continuously variable.
  • Zero Offset (Probe Zero): 0–999.999 μs.
  • Material Velocity Table: Contains longitudinal and shear velocities for a variety of material types.

 

PULSER

  • Pulser Type: Two adjustable square wave pulsers and receivers.
  • P.R.F.: 8 to 333Hz in selectable steps (8, 16, 32, 66, 125, 250, 333Hz).
  • Pulser Voltage: 200 volt peak amplitude, rise/fall time < 10ns into 50ohm.
  • Pulse Width: 40 to 400 ns. Selectable step options (spike, thin or wide).
RECEIVER

  • Gain: 0 to 110dB with 0.2dB resolution. Manual and AGC control.
  • Damping: 50, 75, 100, 300, 600, & 1500 ohms.
  • Frequency Bands: DFX-7 & 7+: Broadband 1.8 – 19 MHz (-3dB). DFX-7+: Three narrow bands centered at 2MHz, 5MHz, 10MHz.
  • Horizontal Linearity: +/- 0.4% FSW.
  • Vertical Linearity: +/- 1% FSH.
  • Amplifier Linearity: +/- 1 dB.
  • Amplitude Measurement: 0 to 100% FSH, with 1% resolution.
  • Delay: 0 – 999in (25,375mm) at steel velocity.

 

FLAW DETECTOR: FEATURES

  • TRIG: Trigonometric display of beam path, depth, surface distance, and curved surface correction. Used with angle beam transducers.
  • DAC: Up to 8 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, (-6/-12), (-6/-14), (-2/-6/-10) dB. Amplitude displayed in %DAC or dB.
  • AWS: Automatic defect sizing in accordance with AWS D1.1 structural welding code.
  • AVG/DGS: Automatic defect sizing using probe data. Stores up to 64 custom setups.
  • TCG: Time corrected gain. 50 dB dynamic range, 20 dB per microsecond, up to 8 points for curve definition.
  • Measurement Mode: Pulse-Echo (P-E) measures from 0.025 in to 100 ft. (0.63mm to 3048 cm).
  • Auto-Cal: Provides automatic calibration with two reference points.
  • Detection Modes: Zero Crossing, Flank and Peak.
  • Display Freeze: Hold current waveform on screen.
  • Peak Memory: For echodynamic pattern determination.

 

THICKNESS GAUGE: FEATURES

  • Measurement Modes (Dual Element):
  • Pulse-Echo Mode (P-E) – (Pit & Flaw Detection) measures from 0.025 in to 100 ft. (0.63mm to 3048 cm).
  • Pulse-Echo Coating Mode (PECT) – (Material, Coating, Pit & Flaw Detection): Material: 0.025 in to 100 ft. (0.63mm to 3048 cm). Coating: 0.001 to 0.100 inches (0.01 to 2.54 millimeters).
  • Pulse-Echo Temp Comp Mode (PETP) – (Pit & Flaw Detection) Auto temperature compensation – measures from 0.025 in to 100 ft. (0.63 mm to 3048 cm).
  • Echo-Echo Mode (E-E) – (Thru Paint & Coatings) measures from 0.050 to 4.0 inches (1.27 to 102 millimeters). Will vary based on coating.
FEATURES, CONT.

  • Echo-Echo Verify (E-EV) – (Thru Paint & Coatings) measures from 0.050 to 1.0 inches (1.27 to 25.4 millimeters). Will vary based on coating.
  • Coating Only Mode (CT) – (Coating Thickness) Measures from 0.0005 to 0.100 inches (0.0127 to 2.54 millimeters). Range will vary +/- depending on the coating.
  • One and two point calibration option for material & coating, or selection of basic material types.
  • Auto probe zero, recognition and temperature compensation.
  • High speed scan up to 50 readings per second.
  • Audible alarm with hi/lo limits.
  • Built-in differential mode for QC inspections.
  • 64 custom setup configurations.

 

MEMORY

  • Log Formats: Grid (Alpha Numeric), or Sequential (Auto Identifier).
  • Graphics On: 8,000 readings, A/B Scan image, & all gauge settings for every reading.
  • Graphics Off: 210,000 readings (coating, material, min & max. (Thickness gauge only).
  • Custom Setups: 64 user configurations.

 

POWER SOURCE

  • Battery: Three 1.5V alkaline, 1.2V AA Nicad cells, 1.2V AA NI-MH, or other other equivalent power source. Battery life (continuous use): Alkaline (12hrs), Nicad (5hrs), and NI-MH (12hrs), with default settings.

 

CONNECTIONS

  • Output: RS232 serial interface. PC software & USB converter cable included.
  • Transducer Connectors: Two LEMO 00 connectors.

 

CERTIFICATION

  • Thickness Gauge: Factory calibration traceable to NIST & MIL-STD-45662A.
  • Flaw Detector: EN12668-1 compliant.

 

WARRANTY

  • 2 year limited

$0.00Price:
Loading Updating cart...

DFX-638

The DFX-638 Digital Ultrasonic Flaw Detector has been designed to meet a variety of application requirements, according to feature sets and performance requirements. It is packaged in an all aluminum housing for rugged working environments.

Additional DescriptionMore Details

The DFX series ultrasonic flaw detectors are full featured digital scopes designed to handle the simplest to the most difficult applications. Whether the application requires high penetration for materials that are difficult to measure, or high resolution for precision aerospace parts, the DFX series flaw detectors are equipped with the necessary features to do the job. They can go where you go, to do the work you do, saving you time and money, making your inspections fast and accurate.

Features:
• Transflective Color TFT Display
• Broad & Narrow Band Amplifier
• Square Wave Pulser (Active Edge)
• Extruded Aluminium Case (IP65)
• Digital Thickness Display
• DAC/TCG/AWS/DGS
• Automatic Calibration
• PC/Video/Analog Outputs
• Long Battery Life (Li-ion pack)
• Large Memory Capacity
• Curved Surface Correction
• Alphanumeric Notes
• Trig function
• Help feature

PHYSICAL

  • Size:9.25 x 7.13 x 4.0 in (235 x 181 x 102mm)
  • Weight:7.5lbs. (3,4Kgs) with Li-Ion cells.
  • Case: Extruded Aluminum.
  • Display: Transflective TFT Color. Display area: 4.39″ x 3.29″ (111.4 x 83.5mm) 320 x 240 pixels. A-Scan area: 255 x 200 pixels (315 x 200 expanded), 8 color options and variable brightness.
  • Temperature:Operating -10 to +55°C or 14 to 131°F
    -20 to +70°C or -4 to 158°F(survivable) Storage -40 to +75°C or -40 to 167°F
  • Environmental: Meets IP65 requirements.

 

SPECIFICATIONS

  • Units: English (in), Metric (mm), or Time (µs).
  • Probe Zero: 0-999.999 µs.
  • Velocity: 0.0100 in/µs (256 to 16000 m/s.
  • Test Range: 0 – 0.05in (1mm) up to 0 – 800in (20,000mm) at steel velocity. Variable in 1, 2, 5 sequence or continuously in 0.05in (1mm) increments. Also from 1 to 5000(µs).
  • Test Modes: Pulse-echo and transmit/receive.
  • Gates: Two fully independent gates with positive and negative triggering for each gate.Two fully independent gates with positive and negative triggering for each gate.
  • Gate Expansion: 635 & 638 Expands range to width of Gate 1.

 

GATE MONITOR DELAY:

  • Selectable 0.6 sec delay on gate 2 negative monitor.

 

MEASUREMENT MODES:

  • Signal Monitor
  • Depth – Depth and amplitude of signal in gate.
  • Echo Echo – Echo-Echo distance, automatic gate 2 position.
  • Gate to Gate – independent gates.
  • Trig – Trigonometric display of beam path, depth and surface distance. Calculation of skip depth and curve surface compensation, X-offset for transducer.
  • T-Min – Holds minimum thickness in depth mode.
MEASUREMENT MODES

  • System Linearity: Vertical = 1% Full Screen Height (FSH) Amplifier Accuracy ±0.1%dB. Horizontal ±0.4% Full Screen Width (FSW).
  • Pulser Voltage: 100V – 350V (450V 638 ) square wave pulser. Pulse width from spike to 2000ns duration – rise/fall times < 5ns into 50 ohms.
  • Pulser Width: Adjustable in 2% of nominal width, minimum 1ns maximum 40ns.
  • ActiveEdge: Unique active pulse control for enhanced near surface resolution and signal response. Replaces traditional damping control.
  • P.R.F.: Selectable 35 to 5000Hz, 5Hz steps.
  • Screen Update Rate: 50 or 60Hz.
  • Rectification: Full wave, positive or negative half wave and unrectified RF.
  • Delay:0 – 800in (20,000mm) at steel velocity in 0.02 steps (0.05mm).
  • Gain: 0 to 110dB. Adjustable in 0.5, 2, 6, 14 and 20dB steps.Frequency Bands: 6 narrow bands centered at 0.5, 1, 2.25, 5, 10 & 15 MHz. Broad band at 2 to 22 MHz (-6dB) and 1 to 35 MHz (-20dB).Vertical Linearity: 1% full screen height.Amplifier Linearity: +/- 0.1 dB.Horizontal Linearity: +/- 0.4% full screen width (FSW).Reject: 80% linear reject.

 

MEMORY

  • Thickness Logging: Storage for 8000 readings stored in Block/Location/Number coding or alpha-numeric pre-programmed work sheets. Transferable to Excel using optional PC software.
  • Panel Memory: 100 storage locations for calibration settings.
  • A-Scan Memory: 800 waveforms.

 

FEATURES

  • Wave Smoothing: Produces a smooth signal envelope.
  • AGC: Automatic Gain Control sets selected echo to a user defined level (10 – 90%).
  • DAC: Up to 10 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, -12, -14 dB curves can be selected for JIS, ASME and EN1714 codes.
  • AWS: Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code.
  • API: Automatic defect sizing in accordance with API 5UE.
FEATURES

  • AVG/DGS: Automatic defect sizing using probe data. 10 probe data sets can be stored.
  • TCG: Time corrected gain. 40 dB dynamic range, 30 dB per microsecond, up to 10 points for curve definition.
  • Auto-Cal: Provides Automatic calibration with two echoes.
  • Reference Waveform: Recalled waveform can be shown in a different color to live waveform for direct comparision.
  • Display Freeze: Hold current waveform on screen.
  • Peak Memory: For echodynamic pattern determination.
  • Online Help: Instant operator guidance on operation accessed from direct key.
  • Language Support: Six user selectable languages from: English, German, French, Spanish, Dutch, Italian, Russian, Polish, Czech, Finnish & Hungarian. Others available on request.

 

POWER SOURCE:

  • Battery: Lithium Ion battery pack 14.4V,
  • 5.0 Amp hrs. Minimum 11 hours use, typical 15 hours, indication of battery charge. Recharge time 4 hours.Charger: 100 – 240 VAC, 50 – 60Hz.

 

CONNECTIONS

  • USB: For connection to PC, keyboard and printer.
  • Outputs: Serial Interface, composite video (NTSC & PAL), analog output for amplitude and distance updated at PRF rate. Transmitter sync output.
  • Transducer Connectors: available withBNC or LEMO 1 connectors (factory option).

 

ADDITIONAL FEATURES:

  • Interface trigger: Interface gate locks to surface echo and eliminates water path variation.High Power Pulser: 450 volt boost.

 

WARRANTY

  • 2 year limited

$0.00Price:
Loading Updating cart...

DFX-635

The DFX-635 Digital Ultrasonic Flaw Detector has been designed to meet a variety of application requirements, according to feature sets and performance requirements. It is packaged in an all aluminum housing for rugged working environments.

Additional DescriptionMore Details

The DFX series ultrasonic flaw detectors are full featured digital scopes designed to handle the simplest to the most difficult applications. Whether the application requires high penetration for materials that are difficult to measure, or high resolution for precision aerospace parts, the DFX series flaw detectors are equipped with the necessary features to do the job. They can go where you go, to do the work you do, saving you time and money, making your inspections fast and accurate.

Features:
• Transflective Color TFT Display
• Broad & Narrow Band Amplifier
• Square Wave Pulser (Active Edge)
• Extruded Aluminium Case (IP65)
• Digital Thickness Display
• DAC/TCG/AWS/DGS
• Automatic Calibration
• PC/Video/Analog Outputs
• Long Battery Life (Li-ion pack)
• Large Memory Capacity
• Curved Surface Correction
• Alphanumeric Notes
• Trig function
• Help feature

PHYSICAL

  • Size:9.25 x 7.13 x 4.0 in (235 x 181 x 102mm)
  • Weight:7.5lbs. (3,4Kgs) with Li-Ion cells.
  • Case: Extruded Aluminum.
  • Display: Transflective TFT Color. Display area: 4.39″ x 3.29″ (111.4 x 83.5mm) 320 x 240 pixels. A-Scan area: 255 x 200 pixels (315 x 200 expanded), 8 color options and variable brightness.
  • Temperature:Operating -10 to +55°C or 14 to 131°F
    -20 to +70°C or -4 to 158°F(survivable) Storage -40 to +75°C or -40 to 167°F
  • Environmental: Meets IP65 requirements.

 

SPECIFICATIONS

  • Units: English (in), Metric (mm), or Time (µs).
  • Probe Zero: 0-999.999 µs.
  • Velocity: 0.0100 in/µs (256 to 16000 m/s.
  • Test Range: 0 – 0.05in (1mm) up to 0 – 800in (20,000mm) at steel velocity. Variable in 1, 2, 5 sequence or continuously in 0.05in (1mm) increments. Also from 1 to 5000(µs).
  • Test Modes: Pulse-echo and transmit/receive.
  • Gates: Two fully independent gates with positive and negative triggering for each gate.Two fully independent gates with positive and negative triggering for each gate.
  • Gate Expansion: 635 & 638 Expands range to width of Gate 1.

 

GATE MONITOR DELAY:

  • Selectable 0.6 sec delay on gate 2 negative monitor.

 

MEASUREMENT MODES:

  • Signal Monitor
  • Depth – Depth and amplitude of signal in gate.
  • Echo Echo – Echo-Echo distance, automatic gate 2 position.
  • Gate to Gate – independent gates.
  • Trig – Trigonometric display of beam path, depth and surface distance. Calculation of skip depth and curve surface compensation, X-offset for transducer.
  • T-Min – Holds minimum thickness in depth mode.
MEASUREMENT MODES

  • System Linearity: Vertical = 1% Full Screen Height (FSH) Amplifier Accuracy ±0.1%dB. Horizontal ±0.4% Full Screen Width (FSW).
  • Pulser Voltage: 100V – 350V (450V 638 ) square wave pulser. Pulse width from spike to 2000ns duration – rise/fall times < 5ns into 50 ohms.
  • Pulser Width: Adjustable in 2% of nominal width, minimum 1ns maximum 40ns.
  • ActiveEdge: Unique active pulse control for enhanced near surface resolution and signal response. Replaces traditional damping control.
  • P.R.F.: Selectable 35 to 5000Hz, 5Hz steps.
  • Screen Update Rate: 50 or 60Hz.
  • Rectification: Full wave, positive or negative half wave and unrectified RF.
  • Delay:0 – 800in (20,000mm) at steel velocity in 0.02 steps (0.05mm).
  • Gain: 0 to 110dB. Adjustable in 0.5, 2, 6, 14 and 20dB steps.Frequency Bands: 6 narrow bands centered at 0.5, 1, 2.25, 5, 10 & 15 MHz. Broad band at 2 to 22 MHz (-6dB) and 1 to 35 MHz (-20dB).Vertical Linearity: 1% full screen height.Amplifier Linearity: +/- 0.1 dB.Horizontal Linearity: +/- 0.4% full screen width (FSW).Reject: 80% linear reject.

 

MEMORY

  • Thickness Logging: Storage for 8000 readings stored in Block/Location/Number coding or alpha-numeric pre-programmed work sheets. Transferable to Excel using optional PC software.
  • Panel Memory: 100 storage locations for calibration settings.
  • A-Scan Memory: 800 waveforms.

 

FEATURES

  • Wave Smoothing: Produces a smooth signal envelope.
  • AGC: Automatic Gain Control sets selected echo to a user defined level (10 – 90%).
  • DAC: Up to 10 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, -12, -14 dB curves can be selected for JIS, ASME and EN1714 codes.
  • AWS: Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code.
FEATURES

  • API: Automatic defect sizing in accordance with API 5UE.
  • AVG/DGS: Automatic defect sizing using probe data. 10 probe data sets can be stored.
  • TCG: Time corrected gain. 40 dB dynamic range, 30 dB per microsecond, up to 10 points for curve definition.
  • Auto-Cal: Provides Automatic calibration with two echoes.
  • Reference Waveform: Recalled waveform can be shown in a different color to live waveform for direct comparision.
  • Display Freeze: Hold current waveform on screen.
  • Peak Memory: For echodynamic pattern determination.
  • Online Help: Instant operator guidance on operation accessed from direct key.
  • Language Support: Six user selectable languages from: English, German, French, Spanish, Dutch, Italian, Russian, Polish, Czech, Finnish & Hungarian. Others available on request.

 

POWER SOURCE:

  • Battery: Lithium Ion battery pack 14.4V,
  • 5.0 Amp hrs. Minimum 11 hours use, typical 15 hours, indication of battery charge. Recharge time 4 hours.Charger: 100 – 240 VAC, 50 – 60Hz.

 

CONNECTIONS

  • USB: For connection to PC, keyboard and printer.
  • Outputs: Serial Interface, composite video (NTSC & PAL), analog output for amplitude and distance updated at PRF rate. Transmitter sync output.
  • Transducer Connectors: available withBNC or LEMO 1 connectors (factory option).

 

WARRANTY

  • 2 year limited

$0.00Price:
Loading Updating cart...

DFX-625

The DFX Series digital ultrasonic flaw detectors have been designed to meet a variety of application requirements, according to feature sets and performance requirements. There are 4 models to select from, according your application demands. These are packaged in an all aluminum housing for rugged working environments.

Additional DescriptionMore Details

The DFX series ultrasonic flaw detectors are full featured digital scopes designed to handle the simplest to the most difficult applications. Whether the application requires high penetration for materials that are difficult to measure, or high resolution for precision aerospace parts, the DFX series flaw detectors are equipped with the necessary features to do the job. They can go where you go, to do the work you do, saving you time and money, making your inspections fast and accurate.

Features:
• Transflective Color TFT Display
• Broad & Narrow Band Amplifier
• Square Wave Pulser (Active Edge)
• Extruded Aluminium Case (IP65)
• Digital Thickness Display
• DAC/TCG/AWS/DGS
• Automatic Calibration
• PC/Video/Analog Outputs
• Long Battery Life (Li-ion pack)
• Large Memory Capacity
• Curved Surface Correction
• Alphanumeric Notes
• Trig function
• Help feature

PHYSICAL

  • Size:9.25 x 7.13 x 4.0 in (235 x 181 x 102mm)
  • Weight:7.5lbs. (3,4Kgs) with Li-Ion cells.
  • Case: Extruded Aluminum.
  • Display: Transflective TFT Color. Display area: 4.39″ x 3.29″ (111.4 x 83.5mm) 320 x 240 pixels. A-Scan area: 255 x 200 pixels (315 x 200 expanded), 8 color options and variable brightness.
  • Temperature:Operating -10 to +55°C or 14 to 131
    -20 to +70°C or -4 to 158°F(survivable) Storage -40 to +75°C or -40 to 167°F
  • Environmental: Meets IP65 requirements.

 

SPECIFICATIONS

  • Units: English (in), Metric (mm), or Time (µs).
  • Probe Zero: 0-999.999 µs.
  • Velocity: 0.0393 to 0.3937 in/µs (1000-9999m/s).
  • Test Range: 0 – 0.2in (5mm) up to 0 – 400in (10,000mm) at steel velocity. Variable in sequence, 0.4in or 0.04in (10mm or 1mm).
  • Test Modes: Pulse-echo and transmit/receive.
  • Gates: Start & Width adjustable over full range. Amplitude 0 -100%, 0.5% steps. Visual & audible alarms. Single gate positive trigger, and two gates positive and negative triggering. Gate 2 has selectable 0.6 second delay on alarm.
  • Depth – Depth and amplitude of signal in gate.
  • Echo Echo – Echo-Echo distance, automatic gate 2 position.

 

MEASUREMENT MODES

  • Depth – Depth and amplitude of signal in gate.
  • Echo Echo – Echo-Echo distance, automatic gate 2 position.
  • Gate to Gate – Echo-Echo , manual gate 2 position.
  • Trig – Trigonometric display of beam path, depth and surface distance. Calculation of skip depth and curve surface compensation, X-offset for transducer.
MEASUREMENT MODES

  • T-Min – Holds minimum thickness in depth mode.
  • System Linearity: Vertical = 1% Full Screen Height (FSH) Amplifier Accuracy ±0.1%dB. Horizontal ±0.4% Full Screen Width (FSW).
  • Pulser Voltage: 200 volt peak amplitude, rise/fall time < 10ns into 50ohm.
  • Pulser Width:fixed at 100ns.
  • ActiveEdge: Unique active pulse control for enhanced near surface resolution and signal response. Replaces traditional damping control.
  • P.R.F.: Selectable 35 to 1000Hz, 5Hz steps.
  • Screen Update Rate: 50 or 60Hz.
  • Rectification: Full wave, positive or negative half wave and unrectified RF.
  • Delay:0 – 400 in (10,000mm)
  • Gain: 0 to 110dB. Adjustable in 0.5, 2, 6, 14 and 20dB steps.
  • Frequency Bands: 4Broadband 1 – 10 MHz (-6dB).
  • Vertical Linearity: 1% full screen height.
  • Amplifier Linearity: +/- 0.1 dB.
  • Horizontal Linearity: +/- 0.4% full screen width (FSW).
  • Reject: 50% suppressive reject. LED warning when selected.

 

MEMORY

  • Thickness Logging: Storage for 8000 readings stored in Block/Location/Number coding or alpha-numeric pre-programmed work sheets. Transferable to Excel using optional PC software.
  • Panel Memory: 100 storage locations for calibration settings.
  • A-Scan Memory: 800 waveforms.

 

FEATURES

  • Wave Smoothing: Produces a smooth signal envelope.
  • AGC: Automatic Gain Control sets selected echo to a user defined level (10 – 90%).
  • DAC: Up to 10 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, -12, -14 dB curves can be selected for JIS, ASME and EN1714 codes.
FEATURES

  • AWS: Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code.
  • API: Automatic defect sizing in accordance with API 5UE.
  • AVG/DGS: Automatic defect sizing using probe data. 10 probe data sets can be stored.
  • Auto-Cal: Provides Automatic calibration with two echoes.
  • Reference Waveform: Recalled waveform can be shown in a different color to live waveform for direct comparision.
  • Display Freeze: Hold current waveform on screen.
  • Peak Memory: For echodynamic pattern determination.
  • Online Help: Instant operator guidance on operation accessed from direct key.
  • Language Support: Six user selectable languages from: English, German, French, Spanish, Dutch, Italian, Russian, Polish, Czech, Finnish & Hungarian. Others available on request.

 

POWER SOURCE:

  • Battery: Lithium Ion battery pack 14.4V,
  • 5.0 Amp hrs. Minimum 11 hours use, typical 15 hours, indication of battery charge. Recharge time 4 hours.Charger: 100 – 240 VAC, 50 – 60Hz.

 

CONNECTIONS

  • USB: For connection to PC, keyboard and printer.
  • Outputs: Serial Interface, composite video (NTSC & PAL), analog output for amplitude and distance updated at PRF rate. Transmitter sync output.
  • Transducer Connectors: available withBNC or LEMO 1 connectors (factory option).

 

WARRANTY

  • 2 year limited

$0.00Price:
Loading Updating cart...

DFX-7

  • Sizing Toolkits: DAC, AWS, TCG, DGS.
  • Exception visibility in sunlight (AMOLED) color VGA display (320×240 pixels).
  • P.R.F. – 8 to 333 Hz, adjustable.
  • Screen Refresh Rate: Adjustable 60 & 120.
  • Detection: Z-Cross, Flank & Peak.
  • Automatic: probe zero, probe recognition, and Temperature compensation.
  • Measurement: Variety of modes to address a number of applications.
  • Large data storage with multiple formats: Alpha numeric grid and sequential w/auto identifier.
  • Windows PC interface software.
  • 2 year limited warranty.
Additional DescriptionMore Details
GENERAL

  • Size: 2.5W x .5H x 1.24D in (63.5 x 165 x 31.5mm).
  • Weight: 14 ounces (.397kgs), with batteries.
  • Case: Extruded aluminum body with nickel plated aluminum end caps (gasket sealed).
  • Display: 1/4 VGA AMOLED color display (320 x 240 pixels). Viewable area 1.7 x 2.27 in (43.2 x 57.6 mm). 16 color pallete, multiple color options, and variable brightness.
  • Screen Refresh Rate: Selectable 60 or 120Hz.
  • Display Views: Flaw Detector: Full wave, +/- Rectified, or RF. Thickness Gauge: Digits, +/- Rectified, RF, or B-Scan.
  • Timing: Precision 25MHz TCXO with single shot 100 MHz 8 bit ultra low power digitizer.
  • Measurement Gates: Two independent gates (Flaw), and three gates (thickness). Start & width adjustable over full range. Amplitude 5-95%, 1% steps. Positive or negative triggering for each gate with audible and visual alarms.
  • Operating Temperature: 14 to 140F (-10C to 60C).
  • Environmental: Meets IP65 requirements.

CALIBRATION

  • Automatic Calibration: Longitudinal (straight), or Shear (angle).
  • Probe Types: Single Contact, Dual, Delay, and Angle .
  • English (in), Metric (mm), or Time (μs).
  • Velocity: 0.0100 to .6300 in/μs (256–16,000 m/s).
  • Test Range: 0 to 0.280in (7.11mm) minimum, to 1200in (30,480mm) maximum at steel velocity. Continuously variable.
  • Zero Offset (Probe Zero): 0–999.999 μs.
  • Material Velocity Table: Contains longitudinal and shear velocities for a variety of material types.

 

PULSER

  • Pulser Type: Two adjustable square wave pulsers and receivers.
  • P.R.F.: 8 to 333Hz in selectable steps (8, 16, 32, 66, 125, 250, 333Hz).
  • Pulser Voltage: 200 volt peak amplitude, rise/fall time < 10ns into 50ohm.
  • Pulse Width: 40 to 400 ns. Selectable step options (spike, thin or wide).
RECEIVER

  • Gain: 0 to 110dB with 0.2dB resolution. Manual and AGC control.
  • Damping: 50, 75, 100, 300, 600, & 1500 ohms.
  • Frequency Bands: DFX-7 & 7+: Broadband 1.8 – 19 MHz (-3dB). DFX-7+: Three narrow bands centered at 2MHz, 5MHz, 10MHz.
  • Horizontal Linearity: +/- 0.4% FSW.
  • Vertical Linearity: +/- 1% FSH.
  • Amplifier Linearity: +/- 1 dB.
  • Amplitude Measurement: 0 to 100% FSH, with 1% resolution.
  • Delay: 0 – 999in (25,375mm) at steel velocity.

 

FLAW DETECTOR: FEATURES

  • TRIG: Trigonometric display of beam path, depth, surface distance, and curved surface correction. Used with angle beam transducers.
  • DAC: Up to 8 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, (-6/-12), (-6/-14), (-2/-6/-10) dB. Amplitude displayed in %DAC or dB.
  • AWS: Automatic defect sizing in accordance with AWS D1.1 structural welding code.
  • AVG/DGS: Automatic defect sizing using probe data. Stores up to 64 custom setups.
  • TCG: Time corrected gain. 50 dB dynamic range, 20 dB per microsecond, up to 8 points for curve definition.
  • Measurement Mode: Pulse-Echo (P-E) measures from 0.025 in to 100 ft. (0.63mm to 3048 cm).
  • Auto-Cal: Provides automatic calibration with two reference points.
  • Detection Modes: Zero Crossing, Flank and Peak.
  • Display Freeze: Hold current waveform on screen.
  • Peak Memory: For echodynamic pattern determination.

 

THICKNESS GAUGE: FEATURES

  • Measurement Modes (Dual Element):
  • Pulse-Echo Mode (P-E) – (Pit & Flaw Detection) measures from 0.025 in to 100 ft. (0.63mm to 3048 cm).
  • Pulse-Echo Coating Mode (PECT) – (Material, Coating, Pit & Flaw Detection): Material: 0.025 in to 100 ft. (0.63mm to 3048 cm). Coating: 0.001 to 0.100 inches (0.01 to 2.54 millimeters).
  • Pulse-Echo Temp Comp Mode (PETP) – (Pit & Flaw Detection) Auto temperature compensation – measures from 0.025 in to 100 ft. (0.63 mm to 3048 cm).
  • Echo-Echo Mode (E-E) – (Thru Paint & Coatings) measures from 0.050 to 4.0 inches (1.27 to 102 millimeters). Will vary based on coating.
FEATURES, CONT.

  • Echo-Echo Verify (E-EV) – (Thru Paint & Coatings) measures from 0.050 to 1.0 inches (1.27 to 25.4 millimeters). Will vary based on coating.
  • Coating Only Mode (CT) – (Coating Thickness) Measures from 0.0005 to 0.100 inches (0.0127 to 2.54 millimeters). Range will vary +/- depending on the coating.
  • One and two point calibration option for material & coating, or selection of basic material types.
  • Auto probe zero, recognition and temperature compensation.
  • High speed scan up to 50 readings per second.
  • Audible alarm with hi/lo limits.
  • Built-in differential mode for QC inspections.
  • 64 custom setup configurations.

 

MEMORY

  • Log Formats: Grid (Alpha Numeric), or Sequential (Auto Identifier).
  • Graphics On: 8,000 readings, A/B Scan image, & all gauge settings for every reading.
  • Graphics Off: 210,000 readings (coating, material, min & max. (Thickness gauge only).
  • Custom Setups: 64 user configurations.

 

POWER SOURCE

  • Battery: Three 1.5V alkaline, 1.2V AA Nicad cells, 1.2V AA NI-MH, or other other equivalent power source. Battery life (continuous use): Alkaline (12hrs), Nicad (5hrs), and NI-MH (12hrs), with default settings.

 

CONNECTIONS

  • Output: RS232 serial interface. PC software & USB converter cable included.
  • Transducer Connectors: Two LEMO 00 connectors.

 

CERTIFICATION

  • Thickness Gauge: Factory calibration traceable to NIST & MIL-STD-45662A.
  • Flaw Detector: EN12668-1 compliant.

 

WARRANTY

  • 2 year limited

$0.00Price:
Loading Updating cart...

DFX-615

The DFX Series digital ultrasonic flaw detectors have been designed to meet a variety of application requirements, according to feature sets and performance requirements. There are 4 models to select from, according your application demands. These are packaged in an all aluminum housing for rugged working environments.

Additional DescriptionMore Details

The DFX series ultrasonic flaw detectors are full featured digital scopes designed to handle the simplest to the most difficult applications. Whether the application requires high penetration for materials that are difficult to measure, or high resolution for precision aerospace parts, the DFX series flaw detectors are equipped with the necessary features to do the job. They can go where you go, to do the work you do, saving you time and money, making your inspections fast and accurate.

Features:
• Transflective Color TFT Display
• Broad & Narrow Band Amplifier
• Square Wave Pulser (Active Edge)
• Extruded Aluminium Case (IP65)
• Digital Thickness Display
• DAC/TCG/AWS/DGS
• Automatic Calibration
• PC/Video/Analog Outputs
• Long Battery Life (Li-ion pack)
• Large Memory Capacity
• Curved Surface Correction
• Alphanumeric Notes
• Trig function
• Help feature

PHYSICAL

  • Size:9.25 x 7.13 x 4.0 in (235 x 181 x 102mm)
  • Weight:7.5lbs. (3,4Kgs) with Li-Ion cells.
  • Case: Extruded Aluminum.
  • Display: Transflective TFT Color. Display area: 4.39″ x 3.29″ (111.4 x 83.5mm) 320 x 240 pixels. A-Scan area: 255 x 200 pixels (315 x 200 expanded), 8 color options and variable brightness.
  • Temperature:Operating -10 to +55°C or 14 to 131°F
    -20 to +70°C or -4 to 158°F(survivable)Storage -40 to +75°C or -40 to 167°F
  • Environmental: Meets IP65 requirements.

 

SPECIFICATIONS

  • Units: English (in), Metric (mm), or Time (µs).
  • Probe Zero: 0-999.999 µs.
  • Velocity: 0.0393 to 0.3937 in/µs (1000-9999m/s).
  • Test Range:  0 – 0.2in (5mm) up to 0 – 400in (10,000mm) at steel velocity. Variable in sequence, 0.4in or 0.04in (10mm or 1mm).
  • Test Modes: Pulse-echo and transmit/receive.
  • Gates: Start & Width adjustable over full range. Amplitude 0 -100%, 0.5% steps. Visual & audible alarms. Single gate positive trigger, and two gates positive and negative triggering. Gate 2 has selectable 0.6 second delay on alarm.
  • Depth – Depth and amplitude of signal in gate.
  • Echo Echo – Echo-Echo distance, automatic gate 2 position.
  • Trig – Trigonometric display of beam path, depth and surface distance. Calculation of skip depth and curve surface compensation, X-offset for transducer.
  • T-Min – Holds minimum thickness in depth mode.
  • System Linearity: Vertical = 1% Full Screen Height (FSH) Amplifier Accuracy±0.1%dB. Horizontal ±0.4% Full Screen Width (FSW).
  • Pulser Voltage: 200 volt peak amplitude, rise/fall time < 10ns into 50ohm.
  • Pulser Width:fixed at 100ns.
SPECIFICATIONS

  • ActiveEdge: Unique active pulse control for enhanced near surface resolution and signal response. Replaces traditional damping control.
  • P.R.F.: Selectable 35 to 1000Hz, 5Hz steps.
  • Screen Update Rate: 50 or 60Hz.
  • Rectification: Full wave, positive or negative half wave and unrectified RF.
  • Delay:0 – 400 in (10,000mm)
  • Gain: 0 to 110dB. Adjustable in 0.5, 2, 6, 14 and 20dB steps.
  • Frequency Bands: 4Broadband 1 – 10 MHz (-6dB).
  • Vertical Linearity: 1% full screen height.
  • Amplifier Linearity: +/- 0.1 dB.
  • Horizontal Linearity: +/- 0.4% full screen width (FSW).
  • Reject: 50% suppressive reject. LED warning when selected.

 

MEMORY

  • Thickness Logging: Storage for 8000 readings stored in Block/Location/Number coding or alpha-numeric pre-programmed work sheets. Transferable to Excel using optional PC software.
  • Panel Memory: 100 storage locations for calibration settings.
  • A-Scan Memory: 800 waveforms.

 

FEATURES

  • Wave Smoothing: Produces a smooth signal envelope.
  • AGC: Automatic Gain Control sets selected echo to a user defined level (10 – 90%).
  • DAC: Up to 10 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, -12, -14 dB curves can be selected for JIS, ASME and EN1714 codes.
  • AWS: Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code.
FEATURES

  • API: Automatic defect sizing in accordance with API 5UE.
  • AVG/DGS: Automatic defect sizing using probe data. 10 probe data sets can be stored.
  • Auto-Cal: Provides Automatic calibration with two echoes.
  • Reference Waveform: Recalled waveform can be shown in a different color to live waveform for direct comparision.
  • Display Freeze: Hold current waveform on screen.
  • Peak Memory: For echodynamic pattern determination.
  • Online Help: Instant operator guidance on operation accessed from direct key.
  • Language Support: Six user selectable languages from: English, German, French, Spanish, Dutch, Italian, Russian, Polish, Czech, Finnish & Hungarian. Others available on request.

 

POWER SOURCE:

  • Battery: Lithium Ion battery pack 14.4V,
  • 5.0 Amp hrs. Minimum 11 hours use, typical 15 hours, indication of battery charge. Recharge time 4 hours.Charger: 100 – 240 VAC, 50 – 60Hz.

 

CONNECTIONS

  • USB: For connection to PC, keyboard and printer.
  • Outputs: Serial Interface, composite video (NTSC & PAL), analog output for amplitude and distance updated at PRF rate. Transmitter sync output.
  • Transducer Connectors: available withBNC or LEMO 1 connectors (factory option).

 

WARRANTY

  • 2 year limited

$0.00Price:
Loading Updating cart...

Gauss Meter

-10-0-10
-20-0-20
-50-0-50

$0.00Price:
Loading Updating cart...

Castrol Strip Type I

or Type II (Field Flux Strips)

$0.00Price:
Loading Updating cart...
Close
E-mail It